·Acquisition of Cell Voltage
·Acquisition of battery temperature
·Passive balancing execution
·Module fan control
·Module fan PWM speed adjustment
·Module fan feedback
·Liquid leakage monitoring
Specifications |
Min. |
Typical |
Max. |
Unit |
||||
BMU-S24PB-A |
BMU-S64PB-A |
|||||||
Auxiliary Power Supply |
Voltage |
9 |
24 |
32 |
V |
|||
Operating Environment |
Temperature |
-25 |
- |
65 |
℃ |
|||
Humidity |
5 |
- |
95 |
% |
||||
Cell Voltage |
Voltage Range |
0 |
- |
5 |
|
|||
Sampling channel |
- |
- |
24 |
64 |
mV |
|||
Insulation Resistance |
- |
100 |
- |
MΩ |
||||
Voltage Resistance |
Rated Operating Voltage |
1500 |
V |
|||||
Voltage |
50Hz/3,000VAC applied between voltage sampling terminal and |
|||||||
Temperature |
Temperature Range |
-40 |
- |
125 |
℃ |
|||
Sampling Points |
- |
- |
24 |
64 |
- |
|||
Sampling Accuracy |
- |
1 |
- |
℃ |
||||
Passive Balancing |
Current |
- |
- |
100mA |
mA |
|||
DI/DO |
DI |
- |
- |
2 |
Channel |
|||
DO |
- |
- |
1 |
Channel |
||||
Singnal Wiring |
Wiring |
- |
- |
Side Connection |
- |