All-in-one Air-cooled ESS Cabinet
ECO-E418LP-A40/69/80
The E418LP series includes models with 400V, 690V, and 800V output options, suitable for different application scenarios and requirements. They feature advanced pack - level liquid cooling and temperature balancing, maintaining cell temperature differences within 3℃. This enhances cell temperature consistency and extends battery life. Its modular design enables flexible parallel configurations and higher energy density, significantly improving the cost - effectiveness, safety, and installation conve-nience of ESS projects.
418 kWh / 1P416S
System Configuration
100-210
kW
Rated Output Power
400-800
V
Rated AC Voltage
89
%
Max. Round Trip Eficiency.
≥ 8,000
Cycle Life
IP55
Ingress Rating
Compact
2㎡ footprint only, easy transportation & fast
installation.
High Integration
418kWh energy in one cabinet with remarkable
endurance.
Efficient Cooling
Optimized in-PACK duct design ensures high-efficiency
cooling with reduced energy consumption.
Long Cycle Life
Over 8,000 cycles, providing excellent long-term
battery performance.
Flexible Expansion
Modular design, simplified parallel expansion.
Ultimate Safety
In-PACK fire warning and protection with
aerosol, prevent heat diffusion and runaway
| DC Side |
ECO-E418LP-A40
ECO-E418LP-A69
ECO-E418LP-A80
|
| Cell Type | LFP / 314 Ah |
| Pack Configuration | 52.248 kWh / 1P52S |
| System Configuration | 418 kWh / 1P416S |
| Rated DC Voltage | 1331.2 V |
| DC Voltage Range |
1164.8 ~ 1497.6 V |
| Max. Charge/Discharge Rate |
0.25 P
0.5 P
0.5 P
|
| Max. Depth of Discharge | 100% (25 ± 2 ℃) |
| AC Side | |
| Rated Output Power |
100 kW
210 kW
210 kW
|
| Rated AC Voltage |
400 V
690 V
800 V
|
| AC Voltage Range | -15%~+10% |
| Grid Type | 3W+PE |
| Rated Frequency | 50 Hz / 60 Hz |
| Power Factor | 0.99/ -1 ~ +1 |
| THDi | ≤ 3% |
| DC Ratio | <0.5% Ipn |
| General | |
| Max. Round Trip Efficiency | 89% |
| Cycle Life | ≥ 8,000 cycles |
| Communication | Modbus TCP/IP |
| Fire Suppression System | Aerosol |
| Ingress Rating | IP55 |
| Cooling | Liquid cooling+Forced air cooling |
| Operating Temperature | -25℃~55℃ (Derating after 45℃) |
| Anticorrosion Rating | C4 (C5 optional) |
| Humidity | 0~95% RH (non-condensing) |
| Noise | ≤ 80 dB |
| Altitude | 3000m (Derating above 2000m) |
| Dimensions (W*D*H) | 1,500*1,350*2,400 mm |
| Weight | 3,800 kg |
| Safety/EMC | UN38.3, IEC62619, IEC63056, IEC62477-1, IEC61000-6-2/4 |
| Grid code | EN50549-1/-10, EN50549-2/-10, PN-EN-50549-1/-2 |